High-force ICT probe for aggressive contact on oxidized or contaminated pads. Supports 10 A instantaneous current for power rail testing. 200 gf spring force breaks through flux residue reliably.
| Overall Length | Plunger Ø | Rated Current | Contact Resistance | Full Stroke | Working Stroke | Spring Force | Temperature Range | Durability |
|---|---|---|---|---|---|---|---|---|
| 33.40 ±0.10 mm | Ø0.90 mm | 3.0 A continuous, 10 A instantaneous | <20 mΩ | 6.40 mm | 4.30 mm | 200 gf ±20% | −40°F–212°F | ≥3,000 cycles |
| Specification | Details |
|---|---|
| Overall Length | 33.40 ±0.10 mm |
| Plunger Ø | Ø0.90 mm |
| Rated Current | 3.0 A continuous, 10 A instantaneous |
| Contact Resistance | <20 mΩ |
| Full Stroke | 6.40 mm |
| Working Stroke | 4.30 mm |
| Spring Force | 200 gf ±20% |
| Temperature Range | −40°F–212°F |
| Durability | ≥3,000 cycles |